Sensors & Quantum Components Beam diagnostics
Diamond Beam Monitors
Measures beam position, intensity or profile.

Good to know
- Fluorescence screens and segmented electrical detectors use different readout methods.
- A thin element can remain in the beam where its attenuation is acceptable.
- The required spatial response determines the sensing geometry.
Specifications
What we define for diamond beam monitors, with units and how each is typically measured. We confirm values for your application in technical review.
Request the datasheetLook up a term in the glossaryDimensions & tolerances
| Parameter | Unit | Typical test method |
|---|---|---|
| Thickness and tolerance (bulk or layer) | mm | Micrometer or optical gauge |
| Lateral size, outline or diameter, and tolerance | mm | Optical measurement |
Crystal & purity
| Parameter | Unit | Typical test method |
|---|---|---|
| Inclusions, growth sectors and defects | Cross-polarised microscopy or birefringence imaging |
Surface & finish
| Parameter | Unit | Typical test method |
|---|---|---|
| Surface finish condition (as-grown, lapped or polished) | Visual inspection to drawing |
Optical performance
| Parameter | Unit | Typical test method |
|---|---|---|
| Radiation type, energy range and beam size | keV | Per application brief |
Electrical & electrochemical
| Parameter | Unit | Typical test method |
|---|---|---|
| Active area or volume | mm² | Optical measurement to drawing |
| Electrode geometry, spacing and metallization | Per drawing | |
| Bias voltage and response | V | Current–voltage and charge-collection test |
| Charge collection distance | µm | Beta-source or ion-beam induced current |
| Dark current and leakage | nA | Current–voltage measurement |
| Contact resistance and ohmic behaviour | Ω·cm² | Transfer-length method |
| Radiation hardness and response stability | Irradiation with post-test response check |
Integration & packaging
| Parameter | Unit | Typical test method |
|---|---|---|
| Operating temperature limit | °C | Per application brief |
| Mounting interface, host fit and attachment | Per drawing | |
| Certificate of conformance and traceability | Supplier declaration |
Where it is used
Requirement to review
Have a material requirement? Let’s review it.
Share your diamond beam monitors requirement, dimensions and drawing for review.